PRODUCTS | |||||
M A R K E T | |||||
Applications | Sentinel data sheet |
Halo data sheet |
Oryx+ data sheet |
DTS Systems | |
![]() |
![]() |
![]() |
![]() |
||
LNG | Leak detection systems for LNG plant. SIL-2 Certified Option. Highest level. ATEX Certified for Hazardous Atmosphere Operation ATEX II(3)G and M(1) |
Short-range leak detection. ATEX Certified Option for Hazardous Atmosphere Operation ATEX II(3)G |
Fully-integrated SIL2-certified leak detection systems for terminals. | ||
Oil and Gas | Leak detection systems for pipelines. Highest level ATEX Certified Option for Hazardous Atmosphere Operation ATEX II(3)G and M(1) |
Shorter-range leak detection in refineries. ATEX Certified Option for Hazardous Atmosphere Operation ATEX II(3)G |
Remote locations networked with Sentinel in control room. | Fully-integrated fibre sensing systems for leak detection and third party intrusion. Extended-range systems available. | |
Power | Long-range used for overtemp & Dynamic Cable Rating (DCR). | Short-range critical links. | Integrated systems for onshore and offshore cables. | ||
Research | Remote locations where data connections are limited; data files stored locally for collection. | ||||
Environmental | Long-range monitoring systems. | Short-range monitoring systems, e.g. dams. | Remote locations. | ||
Mining | ATEX M(1) certified Long-range power cable monitoring, conveyor belt hot spots and ventilation monitoring | Fully integrated ATEX M(1) certified monitoring systems for mining applications |
PRODUCTS | ||||
S P E C I F I C A T I O N | ||||
Specification | Sentinel data sheet |
Halo data sheet |
Oryx+ data sheet |
|
![]() |
![]() |
![]() |
||
Range | 12 km – 45 km | 5 km | 5 km – 30 km | |
Fibre Type | MM or SM | MM | MM | |
Sampling Resolution | 0.5 m - 1 m | 2 m | 0.5 m - 1 m | |
Number of Channels | 1 (Extended with 4-16 Channel Mux) | 4 (Extended with 4-16 Channel Mux) | 4 | |
Input Power | 100 – 240 Vac | 100 – 240 Vac | 12 – 24 Vdc | |
Power consumption | 120 W | 50 W | 30 W to 3 5W | |
Temperature Range | 5°C to 40°C | 5°C to 40°C | -5°C to 60°C (5 km model -40°C to 65°C) | |
ATEX Certification | ATEX M(1) Model AX ATEX II(3)G Model XR |
ATEX II(3)G Model XR | ||
Configuration | Control Room | Control Room | Ruggedised | |
Connectivity | Typically rack mounted with server for connection to Distributed Control Systems (DCS). | Typically rack mounted with server for connection to Distributed Control Systems (DCS). | On board Windows PC suitable for remote locations. |
Notes:
- MM: Multi Mode fiber optic cable.
- SM: Single Mode fiber optic cable.
- MUX: Multiplexer (enables a single DTS to connect to multiple fiber optic cables).
- Sampling Resolution: Distance between two consecutive measuring points, used to outline the temperature profile.
For more information about Sensornet DTS Monitoring Products please visit our contact page or call us on +44 (0)20 8236 2550.